Add pollutants to a simulation
Once a simulation layer has been added and configured, a plume element must be added to introduce pollutants into the simulation before the simulation can be run. There are three types of plume element sources available: Point source, Line source, and Area source.
Add a point source
Use a point source element to introduce pollutants into the simulation from a single cell, similar to how an exhaust stovepipe might. Work through the following steps to add a point source to an existing plume simulation layer:
On the Simulation tab, in the Insert group, click Point source
.The Create Point Source overlay dialog box appears.
Optionally, change the default name of the new point source.
Configure the Emission rate value and define the unit.
Configure the Exit temperature value and define the degree unit.
Configure the Exit velocity value and define the unit.
Configure the Stack height value and define the unit.
Configure the Stack diameter value and define the unit.
Click in the scene to draw the point source.
Optionally, preselect a single point feature—such as an exhaust location—and click the Import geometry from the selected feature button
.The selected geometry is loaded into the new element if it falls within the extent of the simulation layer. If a field alias name exactly matches an input parameter plus unit combination, a field mapping button
appears for each match and the attribute for each field is populated. Click each button to disassociate an attribute and manually enter a replacement value.Click the green check mark
to create the point source.A red inverted cone appears over a red pillar at the clicked location and the point source is added to the simulation in the Contents pane under the Sources heading. The size of the cone is based on the emission rate.
To add more point sources to the simulation, repeat steps 2 through 10 as needed. Alternatively, enable the Auto Apply button to create a point source using the same settings with a single click in the scene.
When you are finished adding point sources, close the overlay dialog box using the Close button
or change the active tool.
Once all source elements have been added, the plume simulation can be run.
Add a line source
Use a line source element to introduce pollutants into the simulation along a linear edge, similar to how vehicles on a freeway might. Work through the following steps to add a line source to an existing plume simulation layer:
On the Simulation tab, in the Insert group, click Line source
.The Create Line Source overlay dialog box appears.
Optionally, change the default name of the new line source.
Configure the Emission rate value and define the unit.
Configure the Release height value and define the unit.
Configure the Line width value and define the unit.
Configure the Initial vertical value and define the unit.
Click in the scene to draw the line source.
Optionally, preselect a single line feature and click the Import geometry from the selected feature button
.The selected geometry is loaded into the new element and clipped to the extent of the simulation layer. If a field alias name exactly matches an input parameter, a field mapping button
appears for each match and the attribute for each field is populated. Click each button to disassociate an attribute and manually enter a replacement value.Double-click or press F2 to finish the drawing.
Click the green check mark
to create the line source.A red line is created along the drawn path and the line source is added to the simulation in the Contents pane under the Sources heading.
To add more line sources to the simulation, repeat steps 2 through 10 as needed. Alternatively, enable the Auto Apply button to create a line source using the same settings when you finish each drawing in the scene.
When you are finished adding line sources, close the overlay dialog box using the Close button
or change the active tool.
Once all source elements have been added, the plume simulation can be run.
Add an area source
Use an area source element to introduce pollutants into the simulation within a polygonal area, similar to how a storage pile might. Work through the following steps to add an area source to an existing plume simulation layer:
On the Simulation tab, in the Insert group, click Area source
.The Create Area Source overlay dialog box appears.
Optionally, change the default name of the new line source.
Configure the Emission rate value and define the unit.
Configure the Release height value and define the unit.
Configure the Initial vertical value and define the unit.
Click in the scene to draw the area source.
Optionally, preselect a single polygon feature and click the Import geometry from the selected feature button
.The selected geometry is loaded into the new element and clipped to the extent of the simulation layer. If a field alias name exactly matches an input parameter plus its unit, a field mapping button
appears for each match and the attribute for each field is populated. Click each button to disassociate an attribute and manually enter a replacement value.Double-click or press F2 to finish the drawing.
Click the green check mark
to create the area source.A red outline with a semitransparent fill is added to the simulation in the Contents pane, under the Sources heading.
To add more area sources to the simulation, repeat steps 2 through 9 as needed. Alternatively, enable the Auto Apply button to create an area source using the same settings when you finish each drawing in the scene.
When you are finished adding area sources, close the overlay dialog box using the Close button
or change the active tool.
Once all source elements have been added, the plume simulation can be run.
Use field mapping to populate an input parameter
When you create a source by importing the geometry of a single selected feature, you can also map an attribute field to an input parameter. When you click the Import geometry from the selected feature button
, a scan of the table is made. A field mapping button
appears next to all parameters where a valid field alias and unit combination are found. Values are automatically loaded from the matching field.
The field alias and unit combination must be exact to use field mapping. Use only a single space to separate the parameter name from the unit, for example: Emission Rate g. If a field alias and unit combination are used more than once in a table, the first encountered instance is mapped.
To unlink a field mapped value, click the field mapping button. That parameter is reenabled and reset to 0.
Point source field mapping values
Use the following table to use field mapping when importing geometry from a selected point feature:
|
Input parameter |
Acceptable field alias values |
|---|---|
|
Emission Rate |
|
|
Exit Temperature |
|
|
Exit Velocity |
|
|
Stack Height |
|
|
Stack Diameter |
|
Line source field mapping values
Use the following table to use field mapping when importing geometry from a selected line feature:
|
Input parameter |
Acceptable field alias values |
|---|---|
|
Emission Rate |
|
|
Release Height |
|
|
Line Width |
|
|
Initial Vertical |
|
Area source field mapping values
Use the following table to use field mapping when importing geometry from a selected polygon feature:
|
Input parameter |
Acceptable field alias values |
|---|---|
|
Emission Rate |
|
|
Release Height |
|
|
Initial Vertical |
|
Modify a source element
The properties of a source element in a simulation layer can be changed after it is created.
To update the location or the properties of an element, right-click the element in the Contents pane and click Modify
.The corresponding overlay dialog box appears.
Adjust the properties or the location of the element.
Click the green check mark
to apply your changes.The simulation must be run again to capture these changes.
On the Simulation tab, in the Build group, click Run
to rebuild the simulation.
Remove a source element
You can remove a source element from the scene and from the simulation.
To remove an element, right-click it in the Contents pane and click Remove
.The simulation must be run again to capture this change.
On the Simulation tab, in the Build group, click Run
to rebuild the simulation.